Viscous Flow Pipe Conductance Calculator (Poiseuille)

Tube Conductance Calculator

P_avg = (P_inlet + P_outlet) ÷ 2

Results

Conductance: — L/s

or — m³/s

Formula: (π · D⁴ · P_avg) ÷ (128 · η · L)

Results are for preliminary estimation only, not a substitute for review by a qualified/licensed engineer.

Introduction

For vacuum system designers sizing roughing and foreline pipework in UHV systems, this calculator provides a defensible first-pass conductance number for a straight tube before committing to a pump or a line diameter. It accurately applies the Poiseuille equation for viscous flow, a model strictly valid for Knudsen numbers (Kn) less than 0.01.

Understanding tube conductance is critical for optimizing system performance, ensuring efficient gas transport, and minimizing pump-down times. This tool helps engineers quickly assess the impact of various pipe dimensions and operating pressures on gas flow in the viscous regime.

How to Use This Calculator

  1. Enter the tube's internal diameter in mm.
  2. Enter the tube length in metres.
  3. Enter the average pressure in Pa, computed as (P_inlet + P_outlet) ÷ 2.
  4. Enter the gas dynamic viscosity in Pa·s and read the conductance in L/s; check that the regime badge has not flagged Kn > 0.01.

FAQ

Q: Which pressure do I enter — inlet, outlet, or average?

A: Average: P_avg = (P_inlet + P_outlet) ÷ 2. Viscous conductance scales linearly with the average pressure in the tube, so entering the higher inlet pressure alone inflates the result.

Q: Why does the calculator say my result is outside the viscous-flow regime?

A: Because the Poiseuille equation applies strictly only while the Knudsen number Kn < 0.01; above that, gas–wall collisions matter and the viscous assumption no longer holds, so the number should not be used as-is.

Q: Does tube conductance depend on pressure?

A: In viscous flow, yes — the computed conductance is proportional to P_avg, so doubling the average pressure doubles the result. That pressure dependence is exactly why the Kn < 0.01 check is built in.

Q: What happens if I enter a small diameter error?

A: It is amplified: diameter enters the formula to the fourth power, so a 2× diameter mistake produces a 16× change in conductance — enter the true internal bore in mm, not the outside diameter.