Van't Riet kLa Calculator
The Van't Riet (1979) correlation estimates the volumetric oxygen transfer coefficient of an aerated stirred tank from the power input per volume and the superficial gas velocity: kLa = K × (P/V)α × vsβ. This calculator applies it in W/m³, m/s and 1/s, reports kLa in 1/s and 1/h, and, when you give the saturation and dissolved oxygen concentrations, the oxygen transfer rate OTR = kLa × (Csat − C).
Superficial gas velocity vs
—m/s
kLa
—1/s
kLa
—1/h
Oxygen transfer rate OTR
—mg/(L·h)
C is above Csat: oxygen leaves the liquid.
How to use the calculator
- Choose the medium. Pick Custom to enter your own K, α and β; otherwise the listed constants are used.
- Enter the power input per volume P/V and choose W/m³ or kW/m³.
- Choose the gas input: the superficial gas velocity vs in m/s or cm/s, or the gas flow Q in m³/h or L/min together with the vessel inner diameter D in m. With Q and D, vs = Q ÷ (π × D² ÷ 4).
- Optionally enter the saturation oxygen concentration Csat and the dissolved oxygen C, both in mg/L, to get the oxygen transfer rate.
- Press Calculate. Read kLa in 1/s and 1/h, the OTR if requested, and the formula with the values used.
About the correlation
- The correlation is empirical (Van't Riet, 1979, Ind. Eng. Chem. Process Des. Dev. 18, 357).
- The non-viscous constants are those applied in a DTU PhD thesis (Pedersen, Eq. S10), developed for reactors up to 2.6 m³; care is needed in other geometries.
- The constants with ions are from the summary table in BioProcess International 23(1-2), 2025, after Gill et al. 2008.
- K varies strongly with the liquid composition, coalescence and the presence of cells, while α and β generally fall between 0.2 and 1.0.
- The correlation loses validity when the impeller floods.
- Such correlations came from high energy microbial fermentation and are not recommended for scaling up cell-culture bioreactors.
Disclaimer: the result is an estimate, not a substitute for kLa measured in the vessel.